Hygienic Valves
Hygienic steam inlet valves are used for the monitored supply of steam in containers or tanks.
Welded flange
For both the mechanical and pneumatic versions, the welded flange is identical and fixed to the valve using four screws.
Internal Assembly
The contact force of the valve seat seal is adjusted using an adjusting nut in the case of valve type DE. In the case of valve type DE PA, adjustment takes place using compressed air in the actuator. All internal assemblies are equipped with a Tefasep® seal by default.
Actuator
Steam inlet valves DE do not have an actuator. Valve type DE PA, on the other hand, is equipped with an air-closing / air-opening pneumatic actuator (LL).
Clamp
Due to its solid construction, the GEA Aseptomag clamp enables a pressure stable and safe connection of the main components. The special design with three segments allows a service-friendly handling of the component, even under tight space conditions.
Feedback units
Steam inlet valves type DE PA (with pneumatic actuator) can be either equipped with feedback units or T.VIS® feedback systems by default. Feedback units from third party suppliers can be mounted via specially designed adaptors. To find out more about feedback units, please click here.
Steam inlet valves type DE are directly welded between a tank and a pipe system and can therefore not be equipped with any feedback options.
Item | Size |
Nominal pressure valve | 12 bar |
---|---|
Closing pressure | approx. 1.5 bar |
Control air pressure | 6 bar |
Internal Assembly | Stainless steel valve stem |
Valve seat seal material | Tefasep® |
Surface quality in product area | Ra ≤ 0.8 |
Material quality in product area | AISI 316L |
Operating temperature | -20...+160°C |
Application | food, dairy, beverage, biotech,
|
Higher closing pressures, other materials, higher surface qualities and higher operating temperatures are available upon request.
The VARIVENT® modular system has many versions available for optimizing the valves in the process system. The portfolio comprises two different control valve types.
Overflow Valves Type Q series VARIVENT® are generally used as pressure relief valves in pipelines.
Hygienic vacuum valves are used to secure lines in processing plants against impermissibly occurring vacuums.
VARIVENT® Safety valves were specially developed for the food, beverage, and pharmaceutical industries and meet all the relevant standards and regulations such as DIN 11866 or ASME BPE.
Companies like GEA process and store large amounts of sensitive data. However, security incidents, from ransomware attacks to physical intrusions and industrial espionage, are ever-expanding. GEA’s effective protection of its business partners’ data – as well as its own proprietary information – is evolving into a competitive advantage. We spoke with Iskro Mollov, GEA’s Chief Information Security Officer, about what it takes to protect a global business in a volatile world.
Resource-efficient fashion has been a long-sought ambition amid the fashion industry’s considerable contributions to global carbon emissions. The need to close the loop by recycling textile fibers into virgin-like materials is higher than ever but seemed like a distant dream until now: Circ, GEA’s American customer and pioneer in the field of textile recycling, might be rewriting the future of the fashion industry.
Alternative proteins are promising – yet still expensive to produce. The usual response is that scaling up will solve this issue. But what if the solution was really about getting better, not just bigger? From more efficient, high-yield processes to upcycling waste heat, engineers are reshaping how we grow food.