OEB5
Rated solutions for all containment challenges
30+
Years of split butterfly valve experience
>1000
Contained installations worldwide
1st
Commercially available split butterfly valve
— Materials handling
Containment throughout the entire process
Exposure and cross contamination can happen at every transfer point. Containment measures keep the product enclosed as it moves from one vessel to the next, and hold that seal through docking, transfer, and disconnection.
However, containment is only as strong as the system surrounding it. To maintain containment performance throughout manufacturing, transfer technology must work seamlessly with the equipment that transports, lifts, stores and delivers materials.

— Containment risk assessment
How much containment you need depends on three things: the potency of the API, the process, and how your operators work. GEA assesses all three against your exposure limits before recommending equipment.
- Dispensing and charging APIs
- IBC transport, blending and discharge
- Feeding granulators and tablet presses
- Cleaning and changeover between campaigns
Request a containment risk assessment to identify potential exposure points and determine the level of containment required for your process, based on the applicable ADI and Rate of Intake limits.

— Highly Potent API
Containment at the source
GEA delivers high containment at the point of transfer, reducing the need for isolators and cumbersome operator PPE while improving ergonomics and ease of operation.
— Our solutions
Contained transfer in and out
No two containment challenges are the same. Depending on the product, process and containment target, some transfers may require permanent, reusable systems, while others can benefit from disposable solutions. Every contained line also needs a way to verify that containment performance is being maintained. These technologies complement each other and can work together within the same installation.
Frequently Asked Containment Questions
Containment requirements and performance
The required containment level depends on the potency of the API, the process conditions, the quantity and frequency of material handled, and how operators interact with the equipment.
GEA can complete a containment risk assessment that evaluates each stage of the process against the Acceptable Daily Intake (ADI) and Rate of Intake (ROI) limits. This identifies where exposure may occur and helps select a suitable containment strategy without under-protecting operators or over-specifying the equipment.
Acceptable Daily Intake (ADI) defines the total amount of a substance that may be safely taken into the body each day.
Rate of Intake (ROI) considers how quickly exposure could occur during a specific process or activity. This is important because a short-duration task, such as docking, sampling or cleaning, may create a significant intake even when the overall daily exposure appears low.
Both values should therefore be considered when defining the required containment performance.
No. An occupational exposure limit defines the maximum acceptable airborne concentration of a substance over a specified period.
Containment performance describes the airborne concentration that equipment or a process can achieve under defined test conditions. The containment solution should provide sufficient protection against the relevant exposure limit while also considering the product’s ADI, ROI and the frequency of each operation.
BUCK® valves provide a containment performance of 1–10 μg/m³ STTWA as standard. Where a higher level of containment is required, the UMC extraction addition can improve performance to below 1 μg/m³ STTWA.
Actual performance depends on the complete installation, including the product characteristics, operating procedure, equipment interfaces, transfer frequency and cleaning method. The valve specification should therefore be considered as part of the complete process risk assessment.
STTWA means Short-Term Time-Weighted Average. It expresses the average airborne concentration measured over a defined short-duration sampling period.
When comparing containment figures, it is important to understand the test conditions, including:
- Sampling duration
- Test material
- Sampling locations
- Transfer quantity
- Number of operating cycles
- Docking and undocking sequence
- Analytical method
A containment figure should not be considered independently of the conditions under which it was achieved.
Containment performance is typically verified through a structured surrogate test using a measurable test powder. Air samples are collected around the equipment while representative operations are performed.
The test may include:
- Docking and undocking
- Opening and closing the transfer interface
- Product transfer
- Container changes
- Sampling
- Cleaning
- Removal of contaminated components
The results are used to assess whether the complete process can achieve the required containment target.
It can. Powder behaviour is affected by properties such as:
- Particle size
- Particle-size distribution
- Dustiness
- Cohesiveness
- Bulk density
- Moisture content
- Electrostatic behaviour
- Flow characteristics
Published equipment performance provides a useful reference, but application-specific assessment or representative testing may still be required.
Equipment selection
The BUCK® MC is designed for high-containment powder transfer under standard pharmaceutical operating conditions.
The BUCK® AC builds on the same containment principle but is intended for more demanding applications involving higher temperatures, pressure rated or aggressive solvents. The most appropriate valve depends on the operating temperature, pressure, cleaning chemistry, solvent exposure and required seal material. The AC valve is pressure rated up to 6 bar in the closed position and 2.5 bar in the open.
Hicoflex® is generally suited to smaller quantities, flexible manufacturing and applications involving frequent product changeovers. Its single-use product-contact components can reduce cleaning, cleaning validation and cross-contamination risks.
A BUCK® split butterfly valve is generally more suitable for repeated transfers, larger quantities and permanent equipment connections where a robust, reusable interface is preferred. GEA offers both BUCK®valves and the Hicoflex® disposable containment system.
The selection should consider:
- Batch and charge size
- Number of transfers
- Product-change frequency
- Cleaning requirements
- Cleaning-validation requirements
- Operator handling
- Waste-disposal strategy
- Consumable requirements
- Total lifecycle cost
Not necessarily. Each stage may involve different quantities, exposure risks, transfer frequencies and levels of operator interaction.
For example, Hicoflex® may be appropriate for dispensing and transferring small quantities, while a BUCK® split butterfly valve may be more efficient for repeated transfers between an IBC and fixed process equipment.
The containment strategy should follow the complete material path, from initial dispensing through transfer, processing, sampling, cleaning and waste handling.
No. A valve is only one part of the containment system. Overall performance also depends on:
- Equipment above and below the valve
- Docking and undocking procedures
- Flexible connections
- Seals and gaskets
- Ventilation and pressure control
- Container handling
- Cleaning and maintenance
- Operator training
- Waste handling
- Powder characteristics
The complete process should be assessed against the product’s applicable ADI, ROI and occupational exposure limits.
Yes, subject to a technical review of the existing equipment and installation.
- A retrofit assessment should consider:
- Available installation height
- Equipment alignment
- Structural loading
- Support requirements
- Access for docking
- Cleaning access
- Required automation
- Existing control architecture
- Safe maintenance access
The passive-to-passive design of the BUCK® allows both passive valve halves to orientate during docking, helping to reduce operator docking error and accommodate alignment within the designed operating limits.
Yes. The appropriate automation level depends on the application, transfer frequency and required level of operator interaction.
Manual systems can provide a simpler solution for lower-frequency operations. Pneumatic or automated systems may be preferred for frequent transfers, integrated process sequences or applications where operator intervention must be minimised.
The BUCK®range extends from manually operated mobile systems to fully automatic pneumatic assemblies.
Seal selection should be based on the complete application, including:
- Product compatibility
- Process solvents
- Cleaning chemicals
- Chemical concentration
- Contact time
- Process temperature
- Operating pressure
- Mechanical duty
- Required conductivity
- Product-contact requirements
BUCK® product-contact elastomer options include white EPDM, black antistatic EPDM and FKM. More demanding solvent applications may require the capabilities of the AC platform with its FFKM seal offering.
Compatibility must be confirmed using the actual combination of chemical, concentration, temperature, pressure and exposure duration.
Cleaning and maintenance
Cleaning should form part of the containment strategy from the beginning of the project. Where possible, contaminated product-contact surfaces should be cleaned before the equipment is opened, disconnected or removed.
Automated wash-in-place (WIP) and clean-in-place (CIP) systems can reduce manual intervention. Single-use interfaces and contained change parts can also reduce direct handling of contaminated components.
BUCK® valves support WIP, CIP and clean-out-of-place strategies, as well as contained changeover of the contaminated valve core.
The cleaning assessment should establish:
- Whether contaminated surfaces become exposed
- How equipment is disconnected
- How residues and wash liquids are drained
- Which components require manual handling
- How seals and filters are changed
- How maintenance is completed safely
Not necessarily. The exposure risk depends on whether the valve has been cleaned, how it is disconnected and whether contaminated surfaces remain contained during removal.
The risk assessment should consider the complete removal procedure, including:
- Pre-cleaning
- Drainage
- Disconnection
- Lifting and handling
- Transport to the cleaning area
- Clean-out-of-place activities
- Maintenance
- Storage
Where removal cannot be completed safely within the required ADI and ROI limits, an alternative cleaning or contained-maintenance arrangement should be considered.
Monitoring and breach response
Containment performance is normally verified during commissioning and through risk-based occupational hygiene testing. However, periodic testing only provides a measurement for the particular period in which the samples are collected.
GEA’s Digital Canary provides continuous, real-time atmosphere monitoring at selected sampling locations. It compares airborne particle readings with an established baseline and can initiate an alarm or corrective action when an out-of-specification condition is detected.
This can provide early warning of a possible containment breach, support preventive maintenance and create an audit trail. It complements rather than replaces equipment qualification, maintenance, cleaning controls and occupational hygiene testing.
The required response should be defined in the site’s containment and emergency procedures.
Depending on the system design, an alarm may:
- Warn operators
- Instruct operators to leave the area
- Stop the process
- Isolate equipment
- Initiate another corrective action
The process should be placed into a safe state, the source of the breach investigated and the area assessed before normal operation resumes.
Digital Canary can inform operators when airborne particle levels have returned to an acceptable baseline, but formal re-entry remains subject to the site’s safety procedure.
Not automatically. Engineering controls should provide the primary method of exposure control, but the required PPE must still be determined by the site risk assessment and operating procedures.
The assessment should consider normal operation, cleaning, maintenance, component removal and foreseeable equipment failures. Real-time atmosphere monitoring can provide an additional layer of protection by identifying abnormal airborne particle levels.
Project definition
The following information provides a good starting point:
- API potency or hazard classification
- ADI
- ROI
- Occupational exposure limit
- Required containment target
- Batch size
- Individual charge size
- Number and frequency of transfers
- Powder characteristics
- Process temperature and pressure
- Solvents and cleaning chemicals
- Existing equipment interfaces
- Cleaning philosophy
- Product-change frequency
- Automation requirements
- Available installation space
- Waste-handling requirements
- Maintenance strategy
Where final exposure limits have not been established, the available toxicological data and provisional potency classification should be reviewed before selecting the equipment.
Both should be considered.
The complete batch determines the total quantity handled during the production period, while individual charges determine the potential exposure associated with each transfer. The assessment should consider:
- Quantity per charge
- Number of charges
- Duration of each activity
- Transfer frequency
- Potential airborne concentration
- Operator proximity
- Time between operations
- Cumulative daily intake
Assessing only the total batch may overlook a significant short-term exposure during an individual charge. Assessing only one charge may overlook the cumulative intake from repeated operations. Both must therefore be evaluated against the applicable ADI and ROI limits.
The assessment should ideally be completed early in the project, before the equipment layout, transfer methods and cleaning philosophy are fixed.
It should also be reviewed when there is a change to:
- Product or potency
- ADI, ROI or occupational exposure limit
- Batch or charge size
- Number of transfers
- Operating procedure
- Equipment configuration
- Cleaning method
- Seal material
- Process temperature or pressure
- Automation level
Early assessment allows containment requirements to be designed into the process rather than added later as a corrective measure.
A well-designed containment system can support:
- Reduced reliance on PPE and administrative controls
- Reduced operator exposure
- More consistent transfers
- Reduced manual cleaning
- Shorter product changeovers
- Reduced cleaning-validation effort
- Improved multi-product flexibility
- Reduced cross-contamination risk
- Improved process repeatability
- Safer cleaning and maintenance
The selected solution should provide the required protection against the applicable ADI, ROI and occupational exposure limits while remaining practical for routine operation, cleaning and maintenance.
Products
Showing 4 of 8

BUCK® AC Containment Valves
The BUCK® AC Valve from GEA brings solvent-resistant functionality to a range of powder transfer applications in multiple industries.

BUCK® MC Containment Valves
BUCK® valves were the first commercially available split valves on the market. Used for the contained transfer of active powders from one vessel to another in pharmaceutical production, BUCK® technology is the result of thousands of successful applications worldwide and more than 15 years of experience.

Digital Canary protects your people
Based on the traditional concept of a live coal-mine canary, the 21st century equivalent from GEA is a continuous real-time monitoring system that’s been designed to detect breaches in contained pharmaceutical production lines. By providing an additional level of monitoring, the Digital Canary reduces the need for routine occupational health chec...

Hicoflex® Single Use Containment System
A disposable high containment Interface for the safe & dust-free transfer of solid dosage material to fully protect your operator, your product and the environment.



