State-of-the-art for your secure applications:
GEA FLOWVENT Mixproof valves are used for the hygienically safe shut-off of incompatible media at pipe intersections.
Function
In the closed state of the valve (non-actuated position) there are always two seals between the separate pipelines. If one seal should become defective, the resulting leakage can flow off from the leakage outlet to the periphery in a targeted manner without mixing with the product in the second pipeline. In this way it is ensured that no mixing occurs between the media in two pipelines.
Application
Hygienic applications in dairy before heat-treatment or e.g. in fermentation and storage tank farms and in the brewing and beverage industries.
Technical data of the standard version
| Recommended flow direction | Against the closing direction |
| Material in contact with product | AISI 316L |
| Material not in contact with product | AISI 304 |
| Seal material in contact with product | EPDM, FKM |
| Ambient temperature | 0 to 45°C |
| Air supply pressure | 6 bar (87 psi) |
| Product pressure | 5 bar (73 psi) |
| Surface in contact with product | Ra ≤ 0,8 μm |
| External housing surface | Matte |
| Control and feedback system | FLOWVENT Control top |
| Actuator type | Pneumatic actuator air / spring |
| Connection fittings | Welding end |
| Identification | Adhesive label |
| Valve seat version | Welded seat ring |
| Certificates | FDA |
Downloads
İlgili Ürünler

FLOWVENT Control top
GEA's state-of-the-art control top technology means you can set-up each installed GEA FLOWVENT valve unit automatically within seconds, even without special training.

FLOWVENT Shut-off valves
The key to guiding your process flow: GEA FLOWVENT Shut-off valves are used for easy shut-off solutions in hygienic applications.

FLOWVENT Double-seal valves
The easy solution for CIP feeds: GEA FLOWVENT Double-seal valves can be applied as efficient alternatives for secure separation of incompatible products within CIP systems or gas blocks.

FLOWVENT Divert valves
The master tool for all changeover functions: GEA FLOWVENT Divert valves are used for easy changeover solutions in hygienic applications.
GEA İçgörüleri

The breakthrough that changed spray drying
In 1976, NIRO engineers responded to a competitive challenge by rethinking what spray drying could do. Their idea became the multi-stage dryer MSD. Fifty years later, the same fundamental principle helps turn liquids into the powders used in essential nutrition products and important medicines around the world. Refined through decades of engineering expertise, customer insight and continuous development, MSD is a story of innovation with lasting impact.

Makineden fazlası: Daha iyi bir tesis performansının kilidini açar
Verimli bir makine, otomatik olarak verimli bir fabrika anlamına gelmez. Gerçek iyileştirme, genellikle münferit ekipmanların ötesine bakıp proseslerin, enerji sistemlerinin ve işletme kararlarının birbirlerini nasıl etkilediğini anlamakla başlar. Bu, normalde gözden kaçırılabilecek fırsatları ortaya çıkarmak üzere tasarlanmış bütünsel bir yaklaşımdır.

Bir vana, yiyecek ve içeceklerin üretilme yöntemini nasıl yeniden şekillendiriyor?
Yiyecek ve içecek tesislerinde, vanalar genellikle tazyikli hava kullanılarak çalıştırılır. GEA Hydract® Actuation Technology, kapalı ve dijital olarak kontrol edilen bir devre içinde vanaları su yardımıyla hareket ettirir. Sonuç, tam olarak yerinde tutulabilen ve hassas ayarlanan adımlarla yönlendirilebilen bir vanadır. Bu, daha az enerji kullanımı ve daha fazla kontrol sağlar.