Hygienic Valves
Hygienic steam inlet valves are used for the monitored supply of steam in containers or tanks.
Welded flange
For both the mechanical and pneumatic versions, the welded flange is identical and fixed to the valve using four screws.
Internal Assembly
The contact force of the valve seat seal is adjusted using an adjusting nut in the case of valve type DE. In the case of valve type DE PA, adjustment takes place using compressed air in the actuator. All internal assemblies are equipped with a Tefasep® seal by default.
Actuator
Steam inlet valves DE do not have an actuator. Valve type DE PA, on the other hand, is equipped with an air-closing / air-opening pneumatic actuator (LL).
Clamp
Due to its solid construction, the GEA Aseptomag clamp enables a pressure stable and safe connection of the main components. The special design with three segments allows a service-friendly handling of the component, even under tight space conditions.
Feedback units
Steam inlet valves type DE PA (with pneumatic actuator) can be either equipped with feedback units or T.VIS® feedback systems by default. Feedback units from third party suppliers can be mounted via specially designed adaptors. To find out more about feedback units, please click here.
Steam inlet valves type DE are directly welded between a tank and a pipe system and can therefore not be equipped with any feedback options.
Item | Size |
Nominal pressure valve | 12 bar |
---|---|
Closing pressure | approx. 1.5 bar |
Control air pressure | 6 bar |
Internal Assembly | Stainless steel valve stem |
Valve seat seal material | Tefasep® |
Surface quality in product area | Ra ≤ 0.8 |
Material quality in product area | AISI 316L |
Operating temperature | -20...+160°C |
Application | food, dairy, beverage, biotech,
|
Higher closing pressures, other materials, higher surface qualities and higher operating temperatures are available upon request.
O sistema modular VARIVENT® apresenta várias versões para otimizar as válvulas no sistema de processamento. O portfólio abrange dois diferentes tipos de válvulas de controle.
As válvulas de sobrefluxo tipo Q VARIVENT® são geralmente usadas como válvulas de alívio de pressão em tubulações.
As válvulas de vácuo higiênicas são usadas para proteger as linhas em plantas de processamento contra a indesejada ocorrência de vácuo.
As válvulas de segurança VARIVENT® foram especialmente desenvolvidas para as indústrias de alimentos, bebidas e farmacêuticas e atendem a todas as normas e regulamentos relevantes, como DIN 11866 ou ASME BPE.
In a dairy herd, every cow has her own story – and modern herd management tools help tell it. By tracking health, habits and needs, these smart systems let farmers care better, work smarter and keep milk flowing. It's the secret behind happy herds and successful, more sustainable dairy farming.
A redução do desperdício é importante para nós na GEA e, ao aproveitar o poder da tecnologia de liofilização, podemos transformar o excedente de alimentos em produtos valiosos e duradouros - ajudando a reduzir o desperdício, a estender a vida útil e a construir uma oferta alimentar mais resiliente para as próximas gerações.